IAM data and variables
Premise reads region, variable, unit and year values from the selected IAM file. Sector mapping files connect those names to the quantities each update uses. The file’s units can differ from inventory units; each sector applies its documented conversions.
Use Scenario coverage and interpretation to check which mappings exist and the file-format section below when preparing your own IAM data. This is separate from the custom package format in External-scenario format.
Production volumes and efficiencies
The mapping between IAM variables and premise variables regarding production volumes and efficiencies can be found in the sector YAML mappings.
Land use and land use change
The mapping between IAM variables and premise variables regarding land use and emissions caused by land use change can be found in the sector YAML mappings.
Carbon Capture and Storage
The mapping between IAM variables and premise variables regarding carbon capture and storage can be found in the sector YAML mappings.
IAM scenario file format
The scenario file should be a comma-separated text file (i.e., csv) with data presented in a tabular format. The following historical rows illustrate the layout; they are not the quickstart scenario:
Model |
Scenario |
Region |
Variable |
Unit |
2005 |
2010 |
2015 |
2020 |
2025 |
|---|---|---|---|---|---|---|---|---|---|
REMIND |
SSP2EU-Base |
CAZ |
Emi|CO2|+|Energy |
Mt CO2/yr |
1011.34074 |
976.7202877 |
993.8525168 |
957.3199102 |
945.014101 |
REMIND |
SSP2EU-Base |
CHA |
Emi|CO2|+|Energy |
Mt CO2/yr |
6720.313463 |
8601.575671 |
10086.37126 |
11281.46999 |
10996.79931 |
REMIND |
SSP2EU-Base |
EUR |
Emi|CO2|+|Energy |
Mt CO2/yr |
4235.648974 |
3730.532814 |
3392.421123 |
3114.284044 |
2860.549231 |
REMIND |
SSP2EU-Base |
IND |
Emi|CO2|+|Energy |
Mt CO2/yr |
1215.466496 |
1664.185158 |
2146.940653 |
2477.459967 |
2946.357462 |
REMIND |
SSP2EU-Base |
JPN |
Emi|CO2|+|Energy |
Mt CO2/yr |
1457.252288 |
1415.666384 |
1345.278014 |
1181.679212 |
1060.684659 |
REMIND |
SSP2EU-Base |
LAM |
Emi|CO2|+|Energy |
Mt CO2/yr |
1410.609298 |
1575.558465 |
1682.930038 |
1613.4512 |
1739.260156 |
REMIND |
SSP2EU-Base |
MEA |
Emi|CO2|+|Energy |
Mt CO2/yr |
1782.408233 |
2254.050107 |
2607.952516 |
2793.972343 |
3064.426497 |
REMIND |
SSP2EU-Base |
NEU |
Emi|CO2|+|Energy |
Mt CO2/yr |
378.1710003 |
421.2277231 |
477.6241091 |
498.465216 |
500.4845903 |
REMIND |
SSP2EU-Base |
OAS |
Emi|CO2|+|Energy |
Mt CO2/yr |
1787.07182 |
2073.863804 |
2442.52372 |
2780.880819 |
3264.746917 |
REMIND |
SSP2EU-Base |
REF |
Emi|CO2|+|Energy |
Mt CO2/yr |
2551.110779 |
2472.637216 |
2544.690495 |
2607.286302 |
2681.647657 |
The following columns must be present:
Region
Variable
Unit
as well as the time steps (e..g, 2005 to 2100). Other columns can be present, but they will be ignored.
You need to point to that file when initiating NewDatabase, like so:
ndb = NewDatabase(
scenarios = [{"model":"remind", "pathway":"my_special_scenario", "year":2028,
"filepath":r"C:\filepath\to\your\scenario\folder"}],
source_db="ecoinvent-3.12-cutoff", # <-- name of the database
source_version="3.12", # <-- version of ecoinvent
)
There are essentially two types of variables needed from the IAM scenario files:
variables that relate to the production volumes of technologies. These variables are used to scale the production volumes of the corresponding activities in the ecoinvent database. For example, if the IAM scenario file contains a variable named
Electricity|Production|Windfor the regionEUR, it will help premise calculate the share of wind power in the electricity consumption mix of that region. Hence, the unit of such variables should refer to a production volume over time (e.g.,GWh/year,EJ/year, etc.).variables that relate to the efficiency of technologies over time. These variables are used to calculate scaling factors (which are relative by default to 2020), to adjust the energy or material efficiency of the corresponding activities in the ecoinvent database. For example, if the IAM scenario file contains a variable named
Electricity|Efficiency|Coalfor the regionEUR, it will help premise adjust the amount of coal and related emissions per unit of kWh produced in that region. Hence, the unit of such variables can be unitless, or relate to an efficiency ratio or percentage.